Milnor 42044CP2 Mantenimiento página 42

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Chapter 3. Routine Maintenance
Figure 18: Cylinder Door Latches
Cylinder Door Latch
1.
Cylinder door latch. Make sure that all door latches can operate easily. Remove lint. If the latch is
damaged or worn, it is necessary to replace the latch (see
your dealer or Milnor. This is not routine maintenance.
2.
Cylinder door on a 42044_ model 42044_ models and all 3-pocket models have two latches on
each cylinder door.
3.
Three panel Rapid Load
models have Rapid Load
.
WARNING
31 : Explosion Hazards—Inner door latches (divided cylinder machines)—A
damaged or improperly seated latch can cause the inner door to open during operation, damaging
the cylinder and shell. A damaged cylinder can rip apart during extraction, puncturing the shell
and discharging metal fragments at high speed.
• Do not operate the machine with any evidence of damage or malfunction.
Figure 19: Air Tight Staph Barriers—42044SP_, 60044SP_, and 72044SP_ Models
Clean Side View of 42044SP_
.
PELLERIN MILNOR CORPORATION
Legend
door. Each panel has two latches. 60044_ and 72044_, two-pocket
doors.
Internal Barrier In Vent
1.
Internal Staph barrier. Make sure the barrier is seated in the
grooves and serviceable.
2.
External staph barrier by others. Make sure caulk is good and
there are no air leaks.
3.
Make sure that the flapper valve is serviceable and has no
particle contamination.
38
Rapid Load
Cylinder
warning statement 31
Flapper Valve
Legend
). Speak to

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

42044np242044sp242044sp342044wp242044wp3