Chapter 3. Routine Maintenance
system must release the compressed air. You can usually hear the sound of the exhaust air for a
short time.
When a compressed air mechanism operates correctly, its time of movement is usually less than
two seconds. The movement is smooth. It does not shake, change speed, or stop in the middle
of travel. A mechanism that does not operate correctly will cause unsatisfactory performance. If
the mechanism does not operate correctly and you cannot repair the problem, speak to your
dealer or Milnor. Possible causes are as follows:
• a blockage or a leak in the air tube,
• a worn pilot air valve,
• worn components in the mechanism,
• air pressure supplied to the machine is not sufficient,
• a component used to remove contamination from the air line is clogged,
• a quick exhaust valve is clogged.
Figure 14: Compressed Air Mechanisms. These are examples. Your machine can look different.
Air Operated Water Valves -
Milnor Air Cylinder Type
Air Operated Water and
Steam Valves - Angle Type
.
PELLERIN MILNOR CORPORATION
Air Operated Drain Valve -
Milnor Air Cylinder Type
Air Operated Water Valve -
Ball Valve Type
34
Air Operated Band Brake -
Milnor Air Cylinder Type
Legend
1.
Factory-set needle valves
to cause two air cylinders
to move together. Do not
adjust.
2.
Quick exhaust valves
3.
Position indicator.
Yellow when valve is
open.
4.
Arrow position indicator

Capítulos