Electrical Connections; Active Unit - ABB Orion3 Extended Instrucciones Originales

Ocultar thumbs Ver también para Orion3 Extended:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66

Electrical connections

Active unit

1
Pin
Wire
Function
RESET
1
White
ACKN.
EDM
2
Brown
Supply
3
Green
MUTING A
4
Yellow
MUTING B
5
Grey
OSSD1
6
Pink
OSSD2
7
Blue
Supply
8
Red
Muting lamp
1
Colors according to ABB Jokab Safety standard cables.
2TLC172298M0201
2015-09-15
Auto. Reset with no function
Auto. Reset with EDM
Manual Reset with no function
Manual Reset with EDM
Connection to
+24 VDC
NC contact of force-guided relay to
+24 VDC
NC contact to +24 VDC
NC contact in series with NC contact of
force-guided relay to +24 VDC
+24 VDC
Muting sensor A
Muting sensor B
Safety control module for ex.
Safety control module for ex.
0 V
Muting lamp and +24 VDC
4
www.abb.com/jokabsafety