Installation
The outputs (OSSD) of the AOPD must be used as machine stopping devices and not as command devices.
The machine must have its own Start command.
The dimension of the smallest object to be detected must be larger than the resolution of the AOPD.
The AOPD must be installed in a room complying with the technical characteristics indicated in paragraph
"Technical data" of the instruction manual.
Do not place the AOPD near strong and/or flashing light sources or similar devices.
Strong electromagnetic interferences can jeopardize the function of the AOPD. Please contact your
ABB Jokab Safety representative for advice.
The operating distance of the device can be reduced in presence of smog, fog or airborne dust.
A sudden change in environment temperature, with very low minimum peaks, can generate a small
condensation layer on the lenses and so jeopardize the function.
Reflecting surfaces placed near the light beams of the AOPD (over, under or laterally) can cause passive
reflections. These reflections can compromise the recognition of an object inside the detection zone.
The Muting/Override function is signaled by a muting/override lamp. Make sure that the lamp has sufficient
lighting and is visibly positioned near the hazard zone.
Make sure to correctly use the muting sensors as described in paragraph "Muting" of the instruction manual.
Avoid incongruent connections that cannot be controlled and thus, exclude undesired potentially dangerous
activations.
Warning! The minimum installation distance must be respected. For more information about its calculation,please
refer to the instruction manual or EN ISO 13855:2010.
Warning! Make sure to test the function and to perform the checks described in paragraph "Checks after first
installation" of the instruction manual before machine start-up.