Working Principle And Operation - Klarstein 10031434 Manual Del Usaurio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Replacement of Batteries
Remove the battery cover plate from the rear of the remote controller. Take out the old batteries. Insert two
new AAA1.5V dry batteries, and pay attention to the polarity. Reinstall the battery cover plate.
• When replacing the batteries, do not use old or different types of batteries, otherwise, it may cause malfunction.
• If the remote controller will not be used for a long time, please remove batteries to prevent batteries from
leaking.
• The operation should be performed in its receiving range.
• It should be kept 1m away from the TV set or stereo sound sets.
• If the remote controller does not operate normally, please take the batteries out and reinsert them after 30
seconds.If it still can't operate properly, replace the batteries.
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient tem-
perature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger,
when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop com-
pressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase room temperature.
This is the heat pump heating principle, its heating capacity will be reduced due to outdoor temperature de-
crease. If outdoor temperature becomes very low, please operate with other heating equipments.
Defrosting:
When outdoor temperature is low but high humidity, after a long while running, frost will form on outdoor unit,
that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop
for 8-10mins. During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop. During the
defrosting, the indoor indicator flashes, the outdoor unit may emit vapor, This is due to the defrosting, it isn't
malfunction. After defrosting finished,the heating will recover automatically.
Anti-cool wind function:
In Heat mode, the following three kinds of status, if indoor heat exchanger hasn't achieve certain temperature
that indoor fan motor will not start, in this way to prevent blowing cool wind (within 3mins): (1) Heat operation
just startedup. (2) After Auto defrosting operation is finished. (3) Heating under low temperature.

Working Principle and Operation

36
Tabla de contenido
loading

Tabla de contenido