Installation of the window sealing board assembly
Half open the window and mount the window sealing
board assembly onto the window, either vertically or ho-
rizontally (see picture). Pull apart the parts of the assem-
bly, adjust the distance of assembly pulled apart so that
the two ends of the assembly come into contact with the
frame, and fasten the parts of the assembly with screws.
Installation of the unit
Move the machine with the heat exhaust hose assembly installed before the window and keep the
unit at least 50 cm away from the walls or other objects. Snap the flat end of the heat exhaust hose
short connector into the elliptical hole of the window sealing board assembly (see picture below).
IMPORTANT: The flat end of the exhaust hose short
connector must be snapped into place. The heat ex-
haust hose may not be bent and shall be free from
significant (greater than 45°) flexure. The exhaust
hose is 280-1500mm long and this length is determi-
ned based on the specification of the air-conditioner.
Do not use prolonged hose or replace with other diffe-
rent hoses as this may affect the functions of the air-
conditioner. The exhaust must be smooth and the air-
conditioner may overheat if the exhaust is obstructed.
Use and Operation
This portable air conditioner has three functions: cooling, dehumidifying and fan. Fan has two speeds:
high and low, setting temperature is 17-30°C, 24 hours timer, sensor and water-level protective function.
Cooling Mode
If the room surrounding temperature is higher than the setting temperature, the cooling is starting.
If the room surrounding temperature is higher than the setting temperature, the compressor stops
and only the fan motor remains working at the set fan speed.
Dry Mode
In the dry mode, if the ambient temperature ≥17°C, the compressor will start. Then, the unit is con-
trolled in the following manner: when the ambient temperature ≤15°V, the compressor shuts down.
When the ambient temperature rises to be ≥17°C, the compressor starts again. The start/stop of the
compressor meets the requirement for 3-minute protection time.
Fan Mode
Under the fan mode, fans runs on both high speed or low speed. Temperature setting is in vain, unit
just displays environment temperature between 10-35°C.
Temperature Setting
The up button and down button may be used to change the set value of the temperature.
15