IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTAL-
LATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE
SYMBOL
CORRECT WORKING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualifi ed "installers of electrical
equipment" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in
which the installation is situated.
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e. for the automation of gates and doors" Any non authorised
modifi cations are to be considered improper and therefore dangerous.
The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local
standards and regulations in force and in particular when the earthing
circuit is not effi cient.
• The programmer is fi tted with an electrical input monitoring system, which
is used to block the motor in emergency conditions; however this system
is not active during the following stages:
- during the fi rst 5 seconds of an opening stage starting from completely
closed
- during the fi rst 2.5 seconds of all other movement stages
Do not therefore attempt to physically block the door during these
stages, otherwise you may risk blowing the motor circuit protection
fuse "F3".
Warning! The presence of the electrical input monitoring system
does not exclude the need to install photoelectric cells or other safety
devices which are foreseen by the local standards and regulations
in force.
• After having installed the device (and before powering up the programmer)
proceed as follows: release the gate (manual release mechanism) and
move it manually, checking that it moves smoothly and has no unusual
points of resistance and that the travel limits activate correctly, then
block the gate again.
• The door can be operated in the manual mode and sent in the closing
direction using the "SEL" button. The door will move while the button is
pressed and stop when it is released.
Warning! The only security devices which can block the movement
of the appliance while operating in the manual mode are the blocking
button and the travel limits. As soon as the door is completely closed
release the "SEL" button.
• Before programing the system, as described in the paragraph 'Programming
procedure' (pag.18), make sure that the gate is completely closed!
Note:
• If you need to check the status of the fuse "F2", disconnect the power supply to
the programmer; reconnect it only after having re-inserted the fuse.
• Never exclude the travel limits during programming.
Warning! The geared motor unit has been assembled in the factory
to be fi tted to the left side of the gate. Read the paragraph on page 16
"instructions for positioning the unit".
OVERALL DIMENSIONS
IMPORTANT REMARKS
. NOT READING THESE IMPORTANT WARNINGS COULD COMPROMISE THE
145
145
290
General characteristics
This product and all its relative components has been designed and manufactured
by Cardin Elettronica who have verifi ed that the product conforms in every
aspect to the safety standard.
Use
The unit 101/SL402409 is suitable for driving sliding gates with weights
of up to 400 kg.
Technical description
• Motor powered with a maximum voltage of 38V dc.
- A two-piece shell made of die cast aluminium contains a never ending
screw and a helicoidal crown wheel made of thermoplastic, lubricated
with permanently fl uid grease.
- The reduction unit stator is made of die cast aluminium and contains a never
ending screw and a helicoidal crown wheel made of thermoplastic lubricated
with permanently fl uid grease.
- Irreversible reduction system with a key operated manual release
mechanism.
- The incorporated electronic programmer contains the power stage, the logic
control and the radio receiver decoding module. The power supply is routed
to the electronics card via a separate transformer which is housed in the same
container and is connected to the card by faston clips.
- Mechanical travel limits in a watertight container.
- Cover in shockproof plastic opened using the manual release mechanism
key.
Accessories
BCC850
- Buffer battery with charging card. The use of the battery
guarantees the supply necessary during blackouts
106/SLOPC
- Toothed rack in glass fi bre 20x20 with upper oval fastening
slits
106/SLOPC1 - Toothed rack in glass fi bre 20x20 with lower oval fastening
slits
950/XLBS03 - Rubber buffer H60 + aluminium support
950/XLBS1
- Pressure switch
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public
safety conditions are satisfi ed:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffi c disruptions and that the size of the gate,
the distance from the road and the work cycle speed can in no way interfere,
causing possible traffi c hazards.
2) The operator must be installed on the inside of the property and not on
the public side of the gate. The gates must not swing outwards onto a
public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) Make sure that the end-user is aware that children and/or pets must not be
allowed to play within the area of a gate installation. If possible include this
in the warning signs (see point 6)
166
20
3
116
42
14
IMPORTANT REMARKS
5