Heat pump water heater – OPERATING AND MAINTENANCE INSTRUCTIONS
7.8 Anti-legionnaire's disease protection (function activated only through the installer menu)
If activated, the water heater automatically carries out the anti-legionnaire's
disease protection function. The water is brought to a temperature of 65 °C on a
monthly basis and for a maximum time of 15 minutes, so as to avoid germs from
developing in the water tank and piping (provided the water has not been
brought to T>57 °C at least once for at least 15 minutes). The first heating cycle
is performed 3 days after the function has been activated. As these temperatures
may cause burns, it is advisable to use a thermostatic mixer.
During the cycle of anti legionnaire's will be displayed "ANTI_B" alternately to the
mode of operation, once the cycle is done the set temperature remains the
original one.
To stop press "on/off".
7.9 Default settings
The appliance is manufactured with a series of default modes, functions or values, as indicated in the table below:
Parameter
PRE-SET TEMPERATURE
MAX. TEMPERATURE SETTABLE WITH THE HEATING
P2
ELEMENT
P3 ANTI-LEGIONNAIRE'S DISEASE PROTECTION
P4 TIME_W (no. Of accepted hours of powering)
P5 HC-HP
PROGRAM P1 TEMPERATURE PRESET
PROGRAM P1 TIME PRESET
PROGRAM P2 TEMPERATURE PRESET
PROGRAM P2 TIME PRESET
7.10 Anti-frost function
In any event, if the temperature of the water in the tank falls below 5 °C while the appliance is powered, the heating
element (1200 W) will be automatically activated to heat the water up to 16 °C.
Factory default setting
55 °C
65 °C
DEACTIVATED
8 h
DEACTIVATED
55 °C
06:00
55 °C
18:00