Heat pump water heater – OPERATING AND MAINTENANCE INSTRUCTIONS
7.6 Information menu
The information menu allows for visualizing data for monitoring the product. To
enter the menu, press the relative knob and hold for 5 seconds.
Turn the knob to select the parameters L1, L2, L3... L9.
The description of the parameter appears on the line below.
Upon reaching the desired parameter, press the knob to visualize its value. Press
the knob or "MODE" button to return to the parameter selection area once again.
To exit the information menu, press "mode" button (the appliance will ensure that the menu is automatically exited
Parameter
Name
L1
T_HIGH
L2
T_LOW
L3
T_DOME
L4
T_AIR
L5
T_EVAP
L6
HP_HOURS
L7
HE_HOURS
L8
SW_MB
L9
SW_HMI
7.7 Installer menu
CAUTION: THE FOLLOWING PARAMETERS MUST BE ADJUSTED BY QUALIFIED PERSONNEL.
Several of the appliance's settings can be modified through the installer menu.
The maintenance symbol is visualized on the left.
To enter the menu, keep the knob pressed for 5 seconds then scroll the
parameters of the "L – INFO" menu until reaching "P1"
Turn the knob to select the parameters P1, P2, P3 ... P6.
Upon reaching the parameter to be modified, press the knob to visualize the
parameter's value then turn the knob to set the desired value.
To return to the parameter selection area, press the knob to store the entered
parameter or press "mode" (or wait 10 seconds) to exit without storing the
entered value.
To exit the installer menu, press the "mode" button (the appliance will
ensure that the menu is automatically exited after the latter has been idle
for 10 minutes).
Name
Parameter
P1
TIME
T_MAX_SET
P2
P3
ANTI_B
P4
TIME_W
P5
HC_HP
P6
RESET
after the latter has been idle for 10 minutes).
Temperature recorded by the heating element unit sensor 1.
Temperature recorded by the heating element unit sensor 2.
Temperature recorded by the hot water pipe sensor.
Temperature recorded by the inlet air sensor.
Temperature recorded by the evaporator sensor.
Meter for internal parameter 1.
Meter for internal parameter 2.
Mainboard software version.
Interface board software version.
Visualization and setting of the current time
Adjustment of the maximum obtainable temperature (from 65 °C to 75 °C).
A higher temperature value allows for using a greater amount of hot water.
Activation/deactivation of the anti-legionnaire's disease function (on/off). See Paragraph 7.8.
Maximum number of hours of daily heating (from 5h to 24h).
HC HP signal parameter, (Keep this parameter OFF)
Resetting of all factory default settings.
Parameter description
Parameter description
34