3 ASSEMBLY INSTRUCTIONS
Prior to assembling your unit, prepare adequate working area to easily work with and
operate your machine.
For "Countertop" model, base may be placed in desired location and begin assembly
procedures at step 5.
For "Floor stand" model, begin assembly procedures at step 1.
Improper installation of the grounding plug can result in a risk of electrical shock.
If repair or replacement of the cord is necessary, ensure that the wire with insulation
having an outer surface that is green with or without yellow stripes is grounded properly.
Check with a qualified electrician or serviceman if the grounding instructions are not
completely understood, or if in doubt as to whether the product is properly grounded.
DO NOT PLUG UNIT IN UNTIL ASSEMBLY IS COMPLETE.
3.1 Step 1 - Preparation for assembly
1)
Remove the packaging from the unit taking care not to cause any damage to unit.
2)
Locate unit in area where it is to operate from. Machines are available in both 110V and
220V; ensure line voltage is suitable for your machine. Machine voltage rating can be found
on the data label on the machine.
3.2 Step 2 - Agitation assembly
1)
Remove Nut Turntable (12) by rotating anticlockwise from the centre Top Plate of the
assembly.
Do not remove shoulder nylon bushing or support washer.
2)
Remove Turntable (31) from its packaging and place on unit locating centre with Brass Swivel
Nut (Figure 3-1), (Shoulder Nylon Bushing and Support Washer should be already in place on
the Brass Swivel Nut).
3)
Once the Turntable is in place, fasten Turntable Nut (12) on Brass Swivel Nut (Figure 3-1).
4)
Insert Crankshaft and Nylon Washer (34) into centre of Brass Swivel Nut (9) (Figure 3-1).
5)
Place Agitator Plate (32) on top of Turntable locating the centre with the Crankshaft (Figure
3-1).
6)
Plug into mains supply and turn the Agitation selector switch to manual (position 1) (chapter
11). The agitation plate should oscillate.
7)
Turn off the Agitation selector switch (position 0) (chapter 11).
7