ERROR DESCRIPTION
Torch protection device not enabled
Incorrect assembly of nozzle holder
No torch recognition at start-up or re-
cognition modified in an invalid state
Electrode end of life
Reed contact closed during striking
Torch error
START button pressed at power up or
during reset after an error
IGBT module over-temperature
Low air pressure at the inlet
24
DISPLAY
LED P
On (flashing:
1 blink + 2 sec. pause)
LED P
On (flashing:
2 blinks + 2 sec. pause)
LED P
On (flashing:
3 blinks + 2 sec. pause)
LED P
On (flashing:
4 blinks + 2 sec. pause)
LED P
On (flashing:
5 blinks + 2 sec. pause)
LED P
On (flashing:
7 blinks + 2 sec. pause)
LED P
On (flashing:
9 blinks + 2 sec. pause)
LED O
On (steadily)
LED Q
On (steadily)
POSSIBLE SOLUTION
Fit the guard
Check that the nozzle holder is correctly
screwed into place
Contact the CEBORA Service Department
Replace electrode and nozzle
Contact the CEBORA Service Department
Contact the CEBORA Service Department
Remove the START command
Do not turn off the power source, so as to
maintain the fan in operation and therefore
obtain effective cooling. Resetting of normal
operation occurs automatically once the
temperature returns within the permitted
limits. If the problem persists, contact the
CEBORA Service
Department.
Increase the gas supply pressure.