Technical Specification; Internal View - DITEC PASM24T Guia Del Usuario

Sensor de movimiento autovigilado para puertas automáticas de ayuda
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Technology
TECHNICAL
SPECIFICATION
Transmitter frequency
Transmitter radiated power : <20 dBm EIRP
Transmitter power density : < 5 mW/cm²
Mounting height
Standard
High
Tilt angles
Detection area (mounting height = 2.2 m)
Wide sensing field
Narrow sensing field
Detection mode
Minimum speed
Supply voltage
Mains frequency
Power consumption
Output configuration in no detection status (current source ON)
Max. open-circuit voltage
Output voltage available at
10mA
Typical load
DESCRIPTION OF
THE SENSOR
INSTALLATION
TIPS
The sensor must be firmly
fastened to prevent
vibrating.
SELFMONITORED MOTION SENSOR FOR AUTOMATIC ESCAPE DOORS
: microwave and
microprocessor
: 24.175 GHz
: from 1.8 m to 3 m
: from 3 m to 4 m
: 0° to 90° vertical
-30° to + 30° lateral
: 4m (W) x 2m (D)
: 2m (W) x 2.5m (D)
: motion
: 5 cm/s (measured in the sensor
axis)
: 12V to 24V AC ±10%
12V to 24V DC +30% /-10%
: 50 to 60 Hz
: < 2W (VA)
: 6.5V
: 3V min.
: up to 3 optocouplers connected
in series.
Free of potential.

INTERNAL VIEW

The sensor must not be
placed behind a panel or
any other material.
Output configuration in detection status (current source OFF)
Leakage current
Open-circuit
remained voltage
Hold time
Temperature range
Degree of protection
Immunity
Dimensions
Weight
Material
Color of housing
Length of cable
Manual adjustment
Sensitivity (by push buttons)
Orientation of sensing field (mechanically)
Shape of the sensing field (by choice of antenna)
Remote control adjustments
Sensitivity
Hold time
Detection mode
Immunity
Mounting height
Door control
Security
Terminal block
Wire opening footprints
Narrow sensing
field antenna
Infrared receiver
LED
Push buttons
Lateral antenna position
adjustment
Wide sensing field antenna
(default)
Vertical antenna position
adjustment
The sensor must not
The sensor must not
have any object likely to
have any fluorescent
move or vibrate in its
lighting in its sensing
sensing field.
field.
PasM24T
USER'S GUIDE
: < 100µA
: < 500mV
: 0.5s to 9s (adjustable)
: -20°C to +55°C
: IP54
: R&TTE 1999/5/EC; EMC 89/336/EEC
: 120 mm (W) x 80 mm (H) x 50 mm (D)
: 0.215 kg
: ABS
: anthracite gray, aluminum finish
or white
: 2.5m
:
10 levels
:
from 0.5s to 9s in 10 levels
:
uni-/bidirectional, MTF, reverse mode
:
quasi-presence, normal, increased
immunities
:
standard, high
:
automatic, permanently open
:
1-4 digit access code
HOUSING
To avoid damage by
electrostatic discharges,
do not touch the
electronic part of the
sensor.
1/8
Tabla de contenido
loading

Tabla de contenido