DITEC PASM24T Guia Del Usuario página 11

Sensor de movimiento autovigilado para puertas automáticas de ayuda
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

A.
MECHANICAL
CONFIGURATION
The sensor has to be set up in such a way that the detection field depth equals at least 1.5m to ensure the installation is TÜV
compliant.
In addition, a technical people has to check at least once a year the integrety of the detection
B. DIMENSIONS OF THE SENSING FIELD (WIDTH, DEPTH, DEAD ZONE) ARE DETERMINED BY THE
C. DIMENSIONS OF THE SENSING FIELD (WIDTH, DEPTH, DEAD ZONE) ARE DETERMINED BY THE
WIDTH OF THE SENSING FIELD DEPENDS ON THE CHOICE OF THE PLANAR ANTENNA
To obtain a wide sensing field,
use the 3-components antenna
The sensing fields (in meter) here on the
right correspond to the following
adjustments:
Vertical angle of antenna : 30° ;
Sensitivity : 9 ;
Bidirectional mode ;
Mounting height : 2.2m.
Remove the narrow
sensing field antenna
from its location.
SENSITIVITY SETTING (0 to 9)
The sensing fields here on the right
correspond to the following adjustments :
Wide sensing field antenna ;
Vertical angle of antenna : 30° ;
Bidirectional mode ;
Mounting height : 2.2m.
MOUNTING HEIGHT
The sensing fields here on the right
correspond to the following adjustments :
Wide sensing field antenna ;
Vertical angle of antenna : 30° ;
Bidirectional mode ;
Sensitivity : 9
Note : For a mounting height from 3m, it is
recommended to set the sensor in the "high
mounting" mode.
WARNING
Carefully remove the clamp of the antenna and the wide
sensing field antenna.
To obtain a narrow sensing field,
use the 6-components antenna
3-components
antenna
6-components
antenna
Put the new antenna on its
header and fix it with the clamp.
m
m
m
m
m
m
3/8
Tabla de contenido
loading

Tabla de contenido