Insertion Of Batteries - DITEC PASM24T Guia Del Usuario

Sensor de movimiento autovigilado para puertas automáticas de ayuda
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1.
FUNCTIONS
CONFIGURATION
WITH REMOTE
CONTROL
0-9 Number keys (1)
Sensitivity (7)
Detection mode (8)
2.
Every adjustment session using the infrared remote control must start with unlocking and end with a double locking.
The table below lists the parameters able to be adjusted by remote control and the operations required in order to adjust these
parameters.
PARAMETERS
UNLOCK
Press the UNLOCK key (4).
Enter your four-digit access code using 0-9 NUMBER keys (1). The access code can be
composed of 1 to 4 digits (factory values or no access code: 0 or 0000)
During the first sensor adjustment or if the access code is reset to the "0000" value
(factory setting) or during the first minute after the power-on, press only the UNLOCK key
(4) (no access code required).
UNLOCK with access code of 4 digits
UNLOCK with access code of less than 4 digits
UNLOCK without access code
LOCK
When all the parameters have been set, press the LOCK key (16).
If you wish to enter a new access code, use 0-9 NUMBER
keys (1) to enter the new four-figure access code within 1 minute.
If no access code is entered or if you want to keep the current access code, press the
LOCK key (16) once more.
If no remote control key is pressed within 1 minute, the adjustment session is automatically
locked.
LOCK with access code change
LOCK without access code or access code change

INSERTION OF BATTERIES

Open the battery compartment at the back of the remote control ;
Insert two AAA batteries supplied with the remote control as shown beside ;
Close the battery compartment.
Not used (2)
Plus (3)
Unlock (4)
Minus (5)
Holdtime (6)
Immunity (9)
CONFIGURATION OF THE SENSOR
OPERATIONS
(10) Not used
(11) Not used
(12) Not used
(13) Mounting Height
(14) Door control
(15) Check Values
(16) Lock
(17) Not used
(18) Not used
(19) Setup
(20) Not used
Note : For optimum results point the remote control to the
sensor before pressing its buttons. The sensor can be adjusted
with or without its cover from a distance up to 5m.
The red LED flashes quickly waiting for the
access code.
After entering the correct access code or if no
access code is required, the red LED flashes
slowly to indicate that the unlock is successful
and the adjustment session has begun.
Note.:
= Adjustment session ON
The red LED stops flashing to return to its normal
function.
LED SIGNAL
5/8
Tabla de contenido
loading