1 Connect the black clip to the neg. pole
3 The following message will be displayed on screen:
After a few seconds, the battery voltage without load
4
will be displayed on screen.
5 Press
6 Select test: Battery
7 Press
Select the battery temperature
8
(Higher than 0°C or Lower than 0°C)
9 Press
Select the test standard (Printed on the battery): EN,
10
SAE, DIN, IEC. For JIS standard, select SAE.
11 Press
Select the battery start-up current.
12
For JIS standard, see the table shown on Page 1 or see
the back of the tester.
13 Press
14 Select battery type:
Standard SLI
VRLA GEL AGM Battery with gelled electrolite
SLA
15 Press
After a few seconds, the result will be displayed on
16
screen.
Battery
Voltage
Power at startup can exceed 100%
7

BATTERY TEST

UNSEALED liquid acid battery
SEALED liquid acid battery
Battery status:
- GOOD
- REPLACE
- GOOD RECHARGE
- RECHARGE – Recharge the battery and repeat the test
and the red clip to the positive pole
Power at startup shown as a
% of nominal current