Chapter 9
9
Technical specifications
Tab. 10:
Technical
specifications
80
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical specifications
9.1
Technical specifications
Parameter
Safety-related parameters
Safety Integrity Level
1)
SIL claim limit
Category
Performance Level
2)
PFH
D
MTTF
d
DC/CCF/Cat.
Type
Actuator coding level
Safe state in case of an
error
T
(mission time) as per
M
EN ISO 13849-1
1)
For detailed information on the safety design of your
machine/system, please contact your local SICK
representative.
2)
Mean probability of a dangerous failure per hour.
1)
SIL2 (IEC 61508)
SILCL2 (EN 62061)
Up to cat. 3 (EN ISO 13849)
PL d (EN ISO 13849)
-7
1.0 × 10
2011 years
87 %/70 %/2
Type 3 (EN ISO 14119)
Uncoded (EN ISO 14119)
At least one safety related
semiconductor output is in the
OFF state.
10 years at –25 ... +70 °C and
rel. humidity of 5 ... 95 %
20 years at +10 ... +40 °C and
rel. humidity of 5 ... 70 %