2
Connection and display elements
1
2
9
8
1
AS−Interface bus connection
2
Earth connection
3
Type plate
4
LED status display for inputs
(green)
5
Sensor connections (PNP)
*
) Valves can be switched off during EMERGENCY STOP, no voltage
supply for the valves via AS−Interface bus
PWR LED Fault LED Meaning
on
off
off
off
flashing
on
on
flashing
on
on
16
3
4
AS−Interface voltage present, no fault
No AS−Interface voltage on the bus
AS−Interface address not set (= 0)
Short circuit/overload at the inputs
Bus communication failure
(watchdog expired)
6
Inscription field for
AS−Interface address
7
LED status display for
valves (yellow)
8
Load voltage connection
for valves
9
PWR LED (power, green),
Fault LED (fault, red)