1.
Change timing cams
B
A
Unplug dryer or disconnect power. Remove meter case service
door by loosening 2 screws securing timer bracket to meter
case and lift timer assembly out.
Remove nylon timing cam (C):
Rotate cam by hand until "V" notch (B) lines up
■
underneath the ratchet tooth.
Insert narrow screwdriver under nylon cam close to the
■
timer shaft. Lift cam gently off shaft (E). Make sure that
pressure is directed upward and the "V" notch clears the
ratchet tooth.
Replace new timing cam:
Be sure drive lug (D) is in place. Place cam (hub down [A])
■
over timer shaft, lining up flat of shaft with flat of drive lug
hole (D).
Rotate cam until "V" notch lines up with ratchet tooth.
■
Press down to seat cam on timer shaft. Make sure that "V"
■
notch freely clears ratchet tooth.
Number of Pins
6 light red
4 light yellow
3 light green
Close and lock the meter case. Plug in dryer or reconnect
power.
C
D
E
Time per Coin Inserted
30
45
60 (installed)
Changing Vend Price
Follow all instructions closely.
The coin chute has been preset at the factory.
When increasing in $0.25 pricing
Follow the instructions found in this section. No extra parts are
required.
When decreasing in $0.25 pricing - or - changing to
$0.10 pricing
A coin sizing block is required; see part numbers following.
Order required parts using Vend Price Change Order Form.
Block-out keys will be shipped to you at no charge. Follow
product information instructions included with replacement
block-out keys.
NOTE: Place all screws and other items removed from coin
slide assembly on a cloth so they will not get lost.
1.
Change timing cams
B
A
Unplug dryer or disconnect power. Open meter case service
door with top-lock key and remove meter case service door.
Remove chute bolt (A) from coin slide mechanism (B) and
remove slide mechanism from meter case (C).
C
19