Cleaning the fine filter
Unpressurize the appliance.
Unscrew the fine filter from the pump
head.
Remove the fine filter and the filter in-
sert.
Clean the filter with clean water or com-
pressed air.
Reinstall in reverse sequence.
Clean the fuel sieve
Knock the dirt off of the fuel sieve. Do
not let the fuel enter the environment.
Clean sieve in the water shortage safe
guard
Remove the fastening clamp and pull
out the hose (soft damping system) of
the lack of water fuse.
Take out sieve.
Note: If necessary turn in screw M8 appr.
0.2 in/5 mm inwards and therewith pull out
sieve.
Clean sieve in water.
Push sieve inwards.
Slide the hose adapter all the way into
the lack of water fuse and secure it with
a fastening clamp.
Clean filter at the detergent suck hose
Take out detergent suck supports.
Clean filter in water and reinstall.
Oil change
Ready a catch bin for appr. 0.26 gal/
1 Liter oil.
Loosen release screw.
Dispose of old oil ecologically or turn in at
a gathering point.
Tighten release screw.
Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifica-
tions.
14
Troubleshooting
Danger
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before
carrying out any tasks on the machine.
Indicator lamp "Ready for use"
No line voltage, see "Appliance is not
–
running".
Fuel indicator lamp glows
Fuel tank empty.
–
Refill fuel.
Indicator lamp for detergent glows
Detergent tank is empty.
–
Refill detergent.
Appliance is not running
No power
–
Check power connection/conduit.
Device is not building up pressure
Nozzle is set to "CHEM"
–
Set nozzle to "High pressure".
Air within the system
–
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device
on and off multiple times with the device
switch.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
If detergent tank is empty, refill.
Check connections and conduits.
Sieve in the water connection is dirty
–
Clean sieve.
Clean the fine filter; replace it, if neces-
sary.
Amount of water supply is too low.
–
Check water supply level (refer to tech-
nical data).
– 8
EN
turns off