Safety; Specifi Cations - Facom NU-712/1200 Guía De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40

Safety

Never take measurements of resistances and diodes on a powered circuit. Never
use on voltage networks higher than 600 Vrms.
Before taking any measurement, make sure the power cables and the selector switch are positioned
correctly.
Never open the tester case before all the electrical sources have been disconnected.
Never connect to the circuit to be measured if the tester case is not closed correctly.
Use accessories complying with standards of safety (EN 61010-2-031), 600 V minimum voltage and
overvoltage category III.
Specifi cations
Overall dimensions
:193 mm x 70 mm x 37 mm
Weight
:260 grams
Opening of alligator clips
:26 mm
1 battery
:9 volts (type 6LF22)
Autonomy
:100 hours or 6,000 measurements of
1 minute each. Automatically turns off
after 10 minutes without the selector
switch or a function button being activated.
NB : Restarted by passing over the selector switch's OFF position or by pressing any button.
Battery discharged indication: A fl ashing battery symbol indicates an
autonomy of less than 1 hour.
A fi xed battery symbol implicates the battery has to be changed.
Operating temperature
:
0° C to + 50° C
Storage temperature
:
- 20° C to + 70° C
Relative humidity in operation
:
< 80 % RH
Relative humidity in storage
:
< 90 % RH
Conformity to standards
: EN 61010.1 (Ed. 95) Class II (double insulation)
: EN 6110.2.032 (Ed. 93)
: EN 61326 (Ed. 98)
Degree of protection
:
IP 40
K 04
Self extinguishing
:
UL 94 V0
Radiated fi elds
:
3 V/m
Free fall
:
1 m
Vibrations
:
.75 mm
Shocks
:
.5 Joule
Electrical shocks
:
6 kV
Electrostatic discharge
:
4 kV class 2
Rapid transients
:
2 kV
Automatic or manual measurement mode selection (AC or DC) (manual mode selected by pressing the
yellow button)
Automatic measurement range selection
Automatic tester turn-off system
Recording functions of the MIN - MAX - PEAK values
Display Hold by pressing the HOLD button (blue button)
Liquid crystal display, 4,000 measuring points (limited to 600 V), 8 mm digit height
Display refresh rate : 400 ms
Backlighting controlled by a manual button (green button)
Automatic display of polarity (+ and -) for DC measurements and PEAK values
Display overLoad indication : OL
DC zeroing to correct for variations
Automatic compensation for resistance of measuring cables in ohmmeter function (Ω zero)
Measuring of currents by clamping
V-Live function. «BEEP» if voltage > 30 V
(up to + 45° C)
Degree of pollution 2
Installation category III
Service voltage 600 V
according to EN 60529(Ed.92)
accordi n g to EN 50102 (Ed. 95)
(according to IEC1000.4.3)
(according to IEC 68.2.32)
(according to IEC 68.2.6)
(according to IEC 68.2.27)
(according to IEC 1000.4.5)
(accordi n g to IEC 1000.4.2)
(according to IEC 1000.4.4)
EN
13
Tabla de contenido
loading

Tabla de contenido