Spectra Precision DG613 Manual De Instrucciones página 32

Ocultar thumbs Ver también para DG613:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 416
Troubleshooting DG813/DG613
Any error message can be deleted with a short press of the E button. The table shows the related description and
possible solutions.
The next service center should be contacted if a different error message as shown at the table will be displayed.
Error codes
Description
21
Temporary EEprom problem
120
LA alert - Unit setup has been changed
130
Mechanical Limit during Spot Match - only at DG813
140
Laser beam blocked - only at DG813
141
Time Out – Automatic alignment or self-leveling could not
be completed in the allowed time
www.kreitel-vermessungsgeraete.de
Solution
Repeat pairing and re-enter the customer settings
Check laser beam elevation/direction
Re-align the closer to the alignment point; check if existing slope
is below/above -12% to +40%
Make sure there are no obstacles between the transmitter and
the SF803
Check radio operating range/ connection; ensure a stable laser
setup
32
Tabla de contenido
loading

Este manual también es adecuado para:

Dg813Sf803Rc803

Tabla de contenido