Manual Spot Search (Dg813) - Spectra Precision DG613 Manual De Instrucciones

Ocultar thumbs Ver también para DG613:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 416
Manual Spot Search Mode (only DG813)
- The Spot Search mode is used for pipe laying by
detecting the beam manually using the Spot Finder SF803 and can be activated in automatic and manual
mode.
Using the "Over the Top" application, the Spot Finder detects the fan beam while the remote control's display
provides the information to position the pipe correctly at the required direction and elevation.
Press and release the M button at the standard display and select Spot Search using the (+)/(-) and left/right
buttons.
Press/release button M  escape/return to the standard display.
Pressing and releasing E button starts the manual Spot Search mode while the beam becomes a rotating fan
beam.
The empty SF symbol indicates the Spot Search mode has been activated.
A black block at the SF symbol indicates the beam position at the Spot finder and gives the direction for
finding the center of the beam. Two black blocks on top or the bottom of the SF symbol confirm the correct
www.kreitel-vermessungsgeraete.de
direction.
4 black blocks at the SF symbol confirm the Spot Finder has been adjusted to the center of the beam which
means the pipe is placed correctly.
Manual Spot Search can be exited any time
by pressing and releasing EL button.
23
Tabla de contenido
loading

Este manual también es adecuado para:

Dg813Sf803Rc803

Tabla de contenido