 Bind the connecting pipe and the cables together tightly with binding tapes.
 Pass the bound connecting pipe through the wall conduct from outside. Be careful of the pipe allocation to do on damage
to the tubing.
 Connect the pipes. Refer to "How to Connect the pipes" for details.
 Expel the air with a vacuum pump. Refer to "How to expel the air with a vacuum pump" for details.
 Open the stop values of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit in
fluent flow.
 Check the leakage. Check all the joints with the leak detector or soap water.
 Cover the joints of the connecting pipe with the soundproof / insulating sheath (fittings), and bind it well with the tapes to
prevent leakage.
Be sure to with insulating materials cover all the exposed parts of the flare pipe joints and refrigerant pipe
!
on the liquid-side and the gas-side. Ensure that there is no gap between them.
CAUTION
Incomplete insulation may cause water condensation.
■ How to take indoor unit apart to connect the pipes
1) Open the front panel
Slide the two stoppers on the left and right sides in word until they click. (see figure below)
2) Remove the front panel
 Remove the string. (see figure below)
 Allowing the front panel to fall forward will enable you to remove it.
3) Remove the face plate
 Remove the screws.
 Opening bottom of face plate for an angle that is 30 degrees, then the top of face plate will be taking up. (Refer to the
figure below)