Dimensional Clearances

Refer to Figure 5 for recommended dimensional
clearances.

Machine Foundation

The machine may be placed on any level floor as long
as floor will hold the weight of the machine.
Position the machine and level with shims or grout
under the corners.
Refer to Table 3 for static loads on the floor.
Floor Load Data
Specification
Static floor load
Static pressure
Table 3
F232212

Installation

6 in.
(152 mm)
840 lbs.
(3.7 kN)
2
68 lbs-ft
2
(3.3 kN-m
)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1/2 in.
(13 mm)
Figure 5

Machine Anchoring

Bolting to floor is optional. To bolt down the machine,
use 3/8 inch bolt holes located on the frame at the
bottom of each corner. One quarter inch machine
anchors should be used.