OPERATION
WARNING: Risk of electric shock.
damp surface, or in water.
WARNING: Risk of Fire and Explosion.
atmospheres. Pump water only with this pump.
1. The shaft seal and impeller depend on water for lubrication and cooling. Do not operate the pump unless it is
pumping water. The seal will be damaged if the pump is allowed to run dry. Fill the pump inlet with water before
each use. Do this before starting the pump.
NOTE: DO NOT run this pump dry. Running this pump dry will void the warranty.
2.
The pump motor requires a fully charged 12V DC battery for operation.
WARNING: Risk of electric shock. Can burn or kill. Before attempting to check why a unit has stopped operating,
disconnect the pump from the battery.
3.
Water should be pumping in 30 seconds or less. If not, make sure that all of the suction connections are air tight. Most
priming problems are due to air leaks in the suction line. Refill the pump inlet and repeat the process. If your pump does not
prime on the second try, disconnect the pump from the battery and refer to Troubleshooting.
NOTE: The motor must have air circulation around it for proper cooling. This pump will lift water 6 ft. Trying to lift
water more than 6 ft. can cause the motor to run hot.
4. Disconnect the pump from the battery before all the water is completely gone. Do not run the pump dry!
MAINTENANCE
When you have finished pumping, disconnect the wires from the power source to be sure the unit is turned off.
NOTE: Use the supplied suction strainer. Keep the pump inlet clear.
Impeller Replacement
Remove the impeller cover screws (4).
Remove the impeller cover (3).
Inspect the O-ring (1) and impeller (2). If the impeller wears out, replace the impeller.
NOTE:Do not disassemble the motor housing of the pump. This motor has NO repairable internal parts, and disassembling
may cause a dangerous electrical wiring issue.
Do not handle a pump or pump motor with wet hands or when standing in a wet or
Can cause severe injury, property damage or death. Do not use in explosive
5