Multi-Channel Operation; Adjusting The Sensitivity (Transmitters Only) - Sennheiser evolution wireless Serie Instrucciones Para El Uso

Ocultar thumbs Ver también para evolution wireless Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SENSIT
EM 100 G2
EM 100 G2
EK 100 G2
32
Starting the scan and storing the scan result
Before starting the scan, switch all transmitters of your system off, since
channels used by switched-on transmitters will not be displayed as "free
channels".
Select the "SCAN" menu.
Select "START" and confirm your selection by pressing the
After the scan is completed, the number of free channels is displayed.
Pressing the
SET
button once more will store the scan result and lock all
channels that are used or subject to interference.
Releasing locked channels
Select the "SCAN" menu.
Select "CLEAR" and confirm your selection by pressing the
channels in this channel bank can now be selected again.

Multi-channel operation

For multi-channel operation, only use the free channels in a channel bank.
Before putting the transmission links into operation, we recommend perfor-
ming an auto scan.
Select a channel bank on a receiver.
Scan this channel bank for free channels. If not enough free channels are
available in the selected channel bank, repeat the scan with another chan-
nel bank.
Apply the scan result to all other transmitters and receivers.

Adjusting the sensitivity (transmitters only)

Via the "SENSIT" menu, you can adjust the modulation level of the transmit-
ters. This changes the transmitter's input sensitivity.
The input sensitivity is adjusted too high when close talking distances, spea-
kers with loud voices or loud music passages cause overmodulation in the
transmission link. In this case, the SK 100 G2's yellow LED (AF PEAK)
light up and the receiver's level display for audio signal (AF) will show full
deflection
(see: „Modulation display of the receiving transmitter" on
page
12).
If, on the other hand, the sensitivity is adjusted too low, the transmission link
will be undermodulated, which would result in a signal with high background
noise.
The sensitivity is correctly adjusted when the level display for audio signal
"AF" shows full deflection only during the loudest passages.
Note:
For monitoring the adjusted sensitivity, the transmitter's level display for
audio signal (AF) always indicates the audio level – even if the transmitter
is muted.
SET