Technical Characteristics - Vimar ELVOX Videocitofonia 7558/E Manual De Instalacion Y Uso

Tabla de contenido
7558/E - 7558/E2
Video entryphone 7558
The instructions manual can be downloaded from the website www.
vimar.com
Description
Wall-mount Tab series hands-free video entryphone for Due Fili
Plus system with 4.3" LCD colour display, loudspeaker for calls,
capacitive keypad for entryphone functions (unlocking, self-starting,
auxiliary services, volume, brightness and contrast controls) and
intercom calls.
Desktop installation is possible with the desktop base accessory
753A (sold separately).
Can be used by wearers of hearing aids.

Technical characteristics

• Wall-mounted, with metal bracket, in box: circular 2M (Vimar
V71701), 3M (Vimar V71303, V71703) vertical and square
British standard.
• LCD 4.3" 16:9 display, resolution 480x272 pixels
• Minimum video signal level on the bus for reception: -20 dBm
• Capacitive touch keypad with backlit symbols.
• Powered from BUS terminals 1, 2 - nominal voltage 28Vdc
• Power consumption:
- in standby: 17 mA
- maximum current: 280 mA
• Ambient class: Class A1 (indoor use)
• IP30 protection rating
• Operating temperature: -5°C to +40°C (indoor use)
• Electronic ringer with 10 different melodies.
• Input for landing call.
• Dimensions: 155 x 145 x 23.5 mm
• DIP switch for line termination impedance.
Audio frequency function for hearing aids (Teleloop)
The video entryphone can be used by people wearing hearing aids.
For correct functioning of the hearing aid, please refer to its
instruction manual. Any metal objects or electronic equipment in the
vicinity may affect the quality of the sound received by the hearing
aid.
Maintenance
Clean using a soft cloth. Do not pour water onto the appliance and
do not use any type of chemical product.
Cleaning must be carried out either with the apparatus powered
off (= disconnected from the bus) or after activating the keypad
cleaning procedure (see the relative paragraph in the user manual).
Warnings for the user
Do not open or tamper with the appliance.
In the event of faults, contact specialized personnel.
10
Key functions
In the subsequent sections of this document the touch keys
are designated as shown in the figure (Fig. 5):
At rest, none of the buttons perform the touch function, but
must be pressed for longer (around 0.4 s): this prevents the
accidental activation of commands. Unless specifically dis-
abled, the recognition notice is given by acoustic signalling.
Buttons T1, T2 and T4 have a default (when not programmed)
which is the one shown in the following figure (Table 1), along
with the default icons: Buttons T2 and T4 can be configured
using the installer menu or with SaveProg.
KEY
ICON
T1
T2
T4
T3 has the function of ringtone mute / mute microphone.
By default, the LOCK
outdoor unit to make a call or the outdoor unit for which self-
start procedure was performed.
In standby mode, the screen is completely switched off. (In
the method described above), by activating any one of the
keys T1..T4 and LOCK
formed without switching on the display unless the function
has to do so in order to be performed, such as self-start.
EN
Table 1
MEANING
Self-start
Aux 2
Aux 1