TROUBLESHOOTING

Malfunction 
Unit does not start up. 
Water flow insufficient 
Insufficient filtering performance 
Insufficient water heating 
(only units with heater) 
The filter cannot be vented. 
Increased noise 
 
MAINTENANCE AND CLEANING 
 If  necessary,  clean  with  clear  water  using  a  soft
brush. 
 Do  not  use  cleaning  agents  or  chemical  solutions. 
We recommend using OASE PumpClean for remov‐
ing calcium deposits. 
 Cleaning and replacement cycles for filter media are 
dependent  on  the  size  of  the  aquarium  and  the 
number  of  fish.  Therefore,  it  is  necessary  to  clean
and replace the filter media as required to ensure
optimum filter performance. 
 If there are several foam filters: Clean or replace the 
foam  filters  at  different  times.  This  saves  enough 
useful  bacteria  to  ensure  good  biological  filtration 
of the water. 
N O T E  
Thoroughly rinse out all filter material with warm tap 
water before using for the first time in order to remove 
any soiling. (→ Cleaning/replacing the filter media) 
16 
Cause 
No mains voltage 
Impeller unit blocked 
Air in the filter 
Impeller unit soiled 
Impeller unit worn 
The flow is not correctly set. 
Foam filter of the pre‐filter soiled 
Filter media in the container soiled 
Suction basket clogged 
Pipework soiled 
Foam filter of the pre‐filter soiled 
Foam filter of the pre‐filter worn 
Filter media in the container soiled 
Filter media in the container worn 
Heater defective 
Heater not calibrated 
Water temperature incorrectly set on the 
heater 
Water flow insufficient 
Valve box in the pre‐filter blocked 
Filter is not below the surface of the water.  Install the filter below the surface of the 
Air in the filter 
BioMaster 250/350/600, BioMaster Thermo 250/350/600
Remedy 
Check the mains voltage. 
Clean 
Vent the filter. Move the filter from side to 
side, if necessary, to allow the remaining air 
to escape. 
Clean 
Replace the impeller unit. 
Correct the setting. 
Clean 
Clean 
Clean 
Clean suction unit, flow‐out unit and hoses. 
Clean 
Replace 
Clean 
Replace 
Replace 
Calibrate 
Correct the water temperature setting on 
the heater. 
See malfunction "Water flow insufficient" 
Clean the valve box. 
water. 
Move the filter from side to side to allow 
the remaining air to escape. 
Cleaning and maintenance work: 
 
Area 
Tasks to be carried out 
Foam filter, pre‐filter  (→ Cleaning/replacing the foam fil‐
ter of the pre‐filter) 
Filter media, contai‐
(→ Cleaning/replacing the filter me‐
ner 
dia) 
Heater 
Impeller unit, pump 
(→ Cleaning/replacing the impeller 
casing 
unit) 
Valve box, pre‐filter 
(→ Cleaning the valve box of the pre‐
filter) 
Suction chamber, pre‐
(→ Cleaning the suction chamber of 
filter 
the pre‐filter) 
N O T E  
The cycle for cleaning the foam filter in the pre‐filter is 
longer if a coarser foam filter is used. 
 
HeatUp 
25/50/100/150/200/300 
Tabla de contenido
loading

Tabla de contenido