COMMANDER2000 (-E)/3000 (-E) AUTOMATIC PROCEDURE
AUTOMATIC SCREEN SETTINGS
The COMMANDER2000 (-E)/3000 (-E) automatic screen will display: hose flushing (COMMANDER3000 (-E) only),
recovery, vacuum, leak test, oil inject (COMMANDER2000 (-E) only) and refrigerant charge:
HOSE FLUSH (COMMANDER3000 (-E) only): This process will flush the machine of any residual oil
•
that is not compatible with hybrid R134a systems. Follow the instructions on the screen
1.
2.
3.
4.
5.
6.
RECOVERY: This procedure is preprogrammed. It cannot be changed in automatic mode.
•
VACUUM: To set the desired amount of vacuum time, press the >> to the right. Set vacuum time on
•
the keypad, press << to lock in time.
LEAK TEST: Vacuum leak testing is available when the vacuum time is 10 minutes or longer. Set the
•
amount of time the leak test will run. Set the time at which the leak test should start.
OIL INJECT (COMMANDER2000 (-E) ONLY): Press the >> to set the desired amount of oil on the
•
keypad. There are three options for oil injection:
Connect the red and blue hoses to the flush / storage fittings on the side of the machine.
Open the couplers by turning the knobs clockwise.
Open the red and blue valves on the machine. Press next.
The flush cycle will now be performed.
Flush complete will be displayed when finished .
Disconnect couplers and attach them to the vehicle AC system.
www.mastercool.com
COMMANDER3000 screen
COMMANDER3000 screen
17