28
9.2.4
SETTING THE CLOCK AND DAILY TIMERS
Alarm set 01 To set the year/month/day:
This command is used to set the year, month and day on the clock in the control board. The introduction
format is YYMMDD.
Alarm set 02 To set the hour and minute:
This command is for setting the hour and minute in the realtime clock built into the electronic control board.
Key in the exact time in hours and minutes and press the B pushbutton to confirm the setting.
The following procedure will set the clock at 10.30:
1. Go into programming mode to display ................................................................................._Command 00_
2. Key in 02 and press the B button to display ............................................................................... _Alarm 00_
3. Key in 2 and press the B button to display the hours and minutes previously set ......................... _NNNN_
4. Key in 1030 and press the B button.
E
N.B. It is necessary to set the clock precisely before using the features for controlling the sale of products by
N
expiry dates and the time controls for switching lamps, discount periods, etc.
G
L
Alarms set 21–24 Set the timed discount bands:
I
These commands are used to set the times when the daily discount periods are switched on and off. During
S
these periods the machine uses prices set in the discount prices submenu. To activate this feature enter the
H
value 1 in Command 62 on the main menu.
For example, to set a discount period lasting from 10.30 to 13.30, proceed as follows:
1. Go into programming mode to display ................................................................................._Command 00_
2. Key in 02 and press the B button to display ............................................................................... _Alarm 00_
3. Key in 21 and press the B button to display the time when discounted prices are first activated ........ _NNNN_
4. Set value to 0000 and press the B button.
5. Key in 22 and press the B button to display the time when discounted prices are first deactivated .... _NNNN_
6. Set value to 1030 and press the B button.
7. Key in 23 and press the B button to display the time when the first discount period ends.................... _NNNN_
8. Set value to 1330 and press the B button.
9. Key in 24 and press the B button to display the time when the second discount period ends .............. NNNN_
10. Set value to 2400 and press the B button.
Alarms set 31-34 Selections disabled for daily time periods:
These commands allow the selections set at command "Alarm 36" to be disabled for two time periods per
day. To set only one disabled time per day, programme as follows:
Alarm set 31 = selection disabled period start
Alarm set 32 = selection disabled period end
Alarm set 33 = second selection disabled period start
Alarm set 34 = second selection disabled period end
If use of this function is not required, programme 2400 at Alarm 31.
Alarm set 36 Setting of selections subjected to hourly disabled periods:
This command allows the choice of selections to be disabled during the time periods in which the "disabled
selections " function is activated (see programming of Alarms 31-34 ). Example:
To activate the hourly disabled time period for selection 15 proceed as follows:
1. Programming mode, the screen displays ...............................................................................Command 00
2. Key in 02 and press B, the screen displays ................................................................................ Alarms 00
3. Key in 36 and press B, the screen displays .........................................................................Selection no.00
4. Key in 15 and press B, the screen displays ......................................................................... En./Dis. 1/0 N
5. Set value 1 and press B.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
[email protected]
Spirali HDR Panzer - Issue 00