Haier GE AB09SC2VHA Instrucciones De Instalación página 7

Ocultar thumbs Ver también para GE AB09SC2VHA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation Instructions: Introduction and Overview
The Cassette Indoor Air Handler ships consists of a cassette
assembly and operational louver. The Cassette Indoor Unit
is operated via a factory supplied remote control. A wired
controller is optional.
The Cassette unit will install between standard dropped ceiling
grids. It is mounted using threaded rods that fit into brackets
that are located at all four corners of the cassette assembly.
The Cassette unit receives 230 volt line voltage from a
connection at the outdoor condensing unit. There is no
requirement for independent line voltage connections.
The cassette unit has a built in condensate pump and
associated float switch that manages the operation of the
condensate pump. A flexible hose is included with the
Cassette unit. This hose connects the cassette condensate
drain outlet to the buildings condensate drain system.
The motorized louver is controlled via the remote control.
The louver has indicator lights that communicate function and
diagnostic information to the user and service technician.
Factory provided insulating tape is included with the cassette
unit. This tape should be placed over the refrigerant piping
connections at the indoor unit to prevent sweating.
Compact Cassette (2'X2') Unit Specifications
Indoor
Rated Cooling Capacity Btu/hr
Rated Heating Capacity Btu/hr
Voltage, Cycle, Phase V/Hz/-
Fan Speed Stages
Airflow (Turbo/High/Med/Low/
Quiet) CFM
Motor Speed (Turbo/High/Med/Low/
Quiet) RPM
Indoor Sound Level dB
(Turbo/High/ Med/Low/Quiet)
Panel Model
Chassis Dimension: Height in (mm)
Chassis Dimension: Width in (mm)
Chassis Dimension: Depth in (mm)
Panel Dimension: Height in (mm)
Panel Dimension: Width in (mm)
Panel Dimension: Depth in (mm)
Weight (Ship/Net)- lbs (kg)
Connections
Liquid O.D. in
Suction O.D. in
Drainpipe Size O.D. in
Internal Condensate Pump
Max. Drain-Lift height in(mm)
31-5000098 Rev. 0
Cassette Product Information
AB09SC2VHA
9,000
10,000
208-230/60/1
5+Auto
410/365/305/265/205
750/690/620/560/500
42/40/36/32/25
PB-700KB (Haier) /
ACP22CWA (GE)
10 1/4 (260)
22 7/16(570)
22 7/16(570)
2 3/8 (60)
27 9/16 (700)
27 9/16 (700)
46.3/37.5 (21/17)
Flare
1/4
3/8
1 1/4
Standard
47 3/16(1,200)
AB12SC2VHA
12,000
13,000
208-230/60/1
5+Auto
410/365/305/265/205
750/690/620/560/500
42/40/36/32/25
PB-700KB (Haier) /
ACP22CWA (GE)
10 1/4 (260)
22 7/16(570)
22 7/16(570)
2 3/8 (60)
27 9/16 (700)
27 9/16 (700)
48.5/40.8 (22/18.5)
Flare
1/4
3/8
1 1/4
Standard
47 3/16(1,200)
Factory Supplied Remote. See
Owner's manual for more information
Wired Controller
is optional
AB18SC2VHA
18,000
19,000
208-230/60/1
5+Auto
470/410/365/295/252
830/750/690/610/550
45/42/40/36/32
PB-700KB (Haier) /
ACP22CWA (GE)
10 1/4 (260)
22 7/16(570)
22 7/16(570)
2 3/8 (60)
27 9/16 (700)
27 9/16 (700)
48.5/40.8 (22/18.5)
Flare
1/4
1/2
1 1/4
Standard
47 3/16(1,200)
7
Tabla de contenido
loading

Este manual también es adecuado para:

Ge ab12sc2vhaGe ab18sc2vha

Tabla de contenido