Sony KP-51WS510 Manual De Servicio página 32

Ocultar thumbs Ver también para KP-51WS510:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SERVICE DATA LISTS
SNNR
Reg.No &Name
FUNCTION
0
SNNR
SNNR data setting
1
SNFX
Selection of SNNR data setting
Noise level detection data thresholds for SNNR data
2
WSLT
SNNR=0/1/2/3
Related to 3D-COMB / #19 YPFG settings
3
CPFG
4
CPFT
Related to 3D-COMB / #18 YPFT settings
5
CCOR
Related to 3D-COMB / #20 VHCO settings
6
CHCG
Related to 3D-COMB /#21 VHCG settings
7
CAPG
Related to 3D-COMB / #16 VAPG settings
8
3SHP
Related to CXA2103 / #6 SHAP settings
9
MIDD
Related to CXA2150P-3 / #19 MIDE settings
Related to CXA2150P-4 / #4 USHP settings
10 5SHP
Related to CXA2150P-3 / #10 F1LV settings
11 5YF1
Related to CXA2150P-3 / #11 CDSP settings
12 5CDS
Related to CXA2150P-3 / #12 LTLV settings
13 5LTI
Related to CXA2150P-3 / #14 CTLV settings
14 5CTI
15 5VML
Related to CXA2150P-3 / #1 UVML settings
16 5YMC
Related to CXA2150P-3 / #3 VMCR settings
ID-1 Detection
Reg.No &Name
FUNCTION
XJGLK:Setting for memorizing or not the ID-1 detection status
0
XJGL
LNJI:Setting for the multi/single-line ID-1 detection
1
LNJI
Closed Caption Display & Parental Control
Reg.No &Name
FUNCTION
Horizontal position of CCD
0
HPRM
Horizontal position of CCD
1
HPRS
OSD rounding control
2
RND
Interruption control
3
CCDI
4
CRIP
CRI count & parity count
5
CRIT
Charge/Discharge timing control for slice voltage level
6
CHMK
Horizontal mask width
7
FPOL
Field polarity selection
8
LANG
9
DATA
Switch for CCD service/test data
Selection of Vchip controls
10 VCHIP
OPTIONS
Reg.No &Name
FUNCTION
Power-On to RLY timing = DLY1 x 50ms
0
DLY1
1
DLY2
Power-On Mute timing =DLY2 x 50ms
2
DLY3
Relay-On to start Bus communication
3
AGC
4
PCMX
5
BRMX
6
RAMW
7
SOFF
0
1
0
0 ~ 30
31 ~ 62
SNNR Settings based on WSL Data
0
1
0
1
0
0
0
1
1
1
0
0
0
1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
1
0
0
1
3
4
0
42
1
0
0
1
2
12
12
255
63
63
0
0
— 33 —
2
3
63 ~ 126
127 ~ 255
2
3
2
3
SNNR data is used for the (-) offset setting.
0
0
SNNR data is used for the direct setting.
1
1
1
1
0
0
2
3
0
0
3
4
SNNR data is used for the (-) offset setting.
2
3
0
0
0
0
0
0
0
0
2
3
SNNR data is used for the (+) offset setting.
KP-51WS510/57WS510/65WS510
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Kp-57ws510Kp-65ws510

Tabla de contenido