Connecting Electricity

Electrical Requirements
This appliance must be installed and grounded on a
branch circuit by a qualified technician in accordance
with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.
All wiring should conform to Local and NEC codes.
This range requires a single-phase, 3 wire, A.C
120/208 V or 120/240 V 60 Hz electrical system. Use
only a 3-conductor or a 4-conductor UL - listed range
cord with closed-loop terminals, open-end spade
lugs with upturned ends or similar termination. Do not
install the power cord without a strain relief.
A range cord rated at 40 amps with 120/208 or
120/240 minimum volt range is required. If a 50 amp
range cord is used, it should be marked for use with
1
/
" diameter connection openings. This appliance
3
8
may be connected by means of a conduit or power
cord. If a conduit is being used, go to page 23 for
3 wire conduit connections or 4 wire conduit
connections.
Gas Flow into Range
"
Adapter
2
WARNING
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack
in the line so that the range can be moved if
servicing is ever necessary.
• The power supply cord and plug should
not be modified. If it will not fit the outlet,
have a proper outlet Installed by a qualified
electrician.
• Using an extension cord to connect the
power is prohibited. Connect the power cord
and plug directly.
• Electrical ground is required on this appliance.
• Make sure that the power cord is not pinched
by the range or heavy objects. Failure to do so
can result in serious burns or electrical shock.
• Do not use a damaged power plug, power
cord, or loose power outlet.
• Do not put a fuse in a neutral or ground circuit.
• Do not connect the ground wire to plastic
plumbing lines, gas lines, or hot water pipes.
Specified power-supply-cord kit rating
Specified
Range rating, watts
rating of
supply-
120/240
120/208
cord kit,
volts
volts
amperes
3-wire
3-wire
8,750 -
7,801 -
40 or 50A
16,500
12,500
16,501 -
12,501 -
22,500
18,500
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)

Connecting the Power Cord

The rear access cover must be removed. Loosen the
two screws with a screwdriver. The terminal block will
then be accessible.
Access cover
INSTALLATION
Diameter (inches)
of Range
connection
power
Opening
Power
Conduit
cord
1
/
"
1
/
3
1
8
8
50
1
/
"
1
/
3
3
4
8
21
"
"