Table 31: Auto-Reset Of Blocks - DWT WaCS PWM Serie Instrucciones De Instalación Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 267
Display message
BL
Block due to water failure
LP
Block due to low line voltage - Reset when specified voltage is restored
Block due to high internal
HP
power supply voltage
Block due to overheating of
OT
final power stages
(TE > 100°C)
Block due to overheating of
OB
printed circuit
(BT> 120°C)
Block due to current
OC
overload on electric pump
motor
Block due to current
OF
overload on final stages of
output
ENGLISH
Automatic reset of error conditions
Description
- One attempt every 10 minutes for a total of 6
attempts
- One attempt every hour for a total of 24 attempts
- One attempt every 24 hours for a total of 30 attempts
- Reset when voltage returns to a specified value
- Reset when temperature of final power stages falls
- Reset when temperature of printed circuit falls below
-
-
-
-
-
-

Table 31: Auto-reset of blocks

128
Automatic reset sequence
below 85°C
100°C
An attempt every 10 minutes for a total of 6
attempts
An attempt every hour for a total of 24 attempts
An attempt every 24 hours for a total of 30
attempts
An attempt every 10 minutes for a total of 6
attempts
An attempt every hour for a total of 24 attempts
- An attempt every 24 hours for a total of 30
attempts
Tabla de contenido
loading

Tabla de contenido