Installation
The gas pipeline connection to the appliance must be done using a rigid metal pipe
and sealing connections.
It is possible to use a hose, but it must:
● Allow for inspection at all times.
● Be protected from possible contact with heatable parts (such as the underside
of the burners).
● Be protected from any stress (torsion, tensile, compression, etc.).
● Be protected from the moving parts of the cabinet (e.g. a drawer).
● Have a maximum length of 1.5 m.
● Be replaced before its expiration date.
Once connected, check the gas circuit seal by using a non-corrosive fluid to detect
any leaks. Do not use a soap and water solution. DO NOT USE AN OPEN FLAME.
5.3 Electrical connections
CAUTION!
This appliance must be connected to a 12 V
mm
cable is used for the connection, its length must not exceed 2
2
meters. When wiring the appliance respect correct polarity!
CAUTION!
Never connect the appliance to the main voltage (230 V~); this would
result in the ultimate destruction of the parts and a hazard to the user.
To connect the appliance, use a double cable and connect it to the terminal board
identified with "+12 V
terminal is the positive pole, while the black terminal is the negative pole.
5.4 Fixing
CAUTION!
This appliance must be fixed to the cabinet using the screws as described
in Fig. 4, page 5.
30
–", found on the back side of the appliance. The red
OVG340I - OV1800 - OVN1800I
power pack. If a 2 x 0,5
EN