DMES−...
If you are using inductive proximity switches
Use switching lugs, sensor supports and proximity switches in accordance with
S
the chapter Accessories".
Use hammer−head screws for fastening
S
the sensor supports in the groove.
The hammer−head screws require the re
cess in the cover as a guide channel. You
can bring the hammer−head screw into the
holding position by turning it 90°.
Avoiding dirt
Use cover rails (groove covers) in all
S
unused grooves in accordance with the
chapter Accessories".

Fitting circuitry

Use the DMES−... only in conjunction with
S
a separately switched emergency stop
mechanism.
*) Emergency stop switching unit
(z) Controller
(x) Emergency stop circuit
Festo DMES−... 0505NH English