4. Add grease EM
(Table
5
operates at 60 Hz, the specified grease quantity for each grease fitting is 0.65 fl oz (18.4
mL).
5. If the motor has a grease drain plugs, operate the machine or use manual functions to operate
the motor for two hours. Replace the drain plug.
Table 11: Motor Grease Intervals and Quantities. Use grease EM
On Motor Nameplate (see
NEMA (IEC)
RPM Less Than
Frame Size
or Equal To
Up to 210 (132)
>210 to 280 (132
to 180)
>280 to 360 (180
to 200)
>360 to 5000
(200 to 300)
10) with the motor stopped. If the motor with the nameplate in
Figure
5)
Interval
Years
900
5.5
1200
4.5
1800
3
3600
1.5
900
4.5
1200
3.5
1800
2.5
3600
1
900
3.5
1200
3
1800
2
3600
0.5
900
2.5
1200
2
1800
1
3600
0.5
29
Chapter 3. Routine Maintenance
(Table
10)
Quantity
Fluid
Hours
Ounces
11000
9000
0.34
6000
3000
9000
7000
0.65
5000
2000
7000
6000
0.87
4000
1000
5000
4000
2.23
2000
1000
PELLERIN MILNOR CORPORATION
Figure
mL
9.5
18.4
24.6
63.2