able depend on the type and model of control unit used.
EN
The "Table of commands" of each control unit is provided in
the instruction manual of the relative control unit.
3 – PRODUCT INSTALLATION
Install the receiver by plugging it into the control unit (fig. 1).
Caution! – Before connecting or removing the receiver,
disconnect the control unit from the power supply.
The aerial supplied must also be installed, connecting it to the
specific terminals on the control unit.
Installation of an external aerial
If the aerial supplied is in an unfavourable position and the
radio signal is weak, an external aerial may be installed to
improve reception. The new aerial must be positioned as high
as possible and above any metal or reinforced concrete struc-
tures present in the area.
– Connection to the Control Unit: Use a coaxial cable with
an impedance of 75ohm. Caution! – To reduce signal dis-
persion use a cable that is as short as possible (not exceed-
ing 10 m).
2