Safety; Explosion Protection; Method 1: Explosion Relief Venting - Nederman E-PAK 150 DX Manual De Instrucciones

Ocultar thumbs Ver también para E-PAK 150 DX:
Tabla de contenido
EN
E-PAK 150 DX/300 DX/500 DX
4

Safety

To maintain a high level of safety when using E-PAK 150 DX/300 DX/500 DX,
consider the following:
This unit is to be installed, used and maintained according to this
document in such a way that safety is maintained. This document contains
important warning directions which have to be observed. Any functional
faults, especially those affecting the safety of the machine, are to be
rectified immediately.
We recommend that fire alarms and appropriate extinguishing systems are
to be installed at all locations where collected combustible dust is stored.
Standards relating to the connection and use of filters in hazardous
areas are to be taken into consideration, especially national standards
for installation. Only trained personnel familiar with these standards is
allowed to handle this type of filters.
This unit was specially designed to comply with official regulations
concerning the risk of explosion. If improperly used, incorrectly installed,
or altered, no matter to which extent, the safety and reliability could be
jeopardized.
For E-PAK 150 DX/300 DX/500 DX to function properly and fulfil the
necessary safety requirements as stated in the declaration of conformity,
the complete system is to be assessed with regards to applicable safety
standards and directives and comply with all requirements described in
this document.
The designer of the system as a whole, has to guarantee the correct
function of all interacting products or components and ensure that the
complete system meets all necessary safety requirements.
Only authorized personnel is allowed to have access to this unit.
WARNING!
Stop operation and clean the entire filter thoroughly from dust before any
grinding, welding or other hot works are performed on the filter exterior or
inlet.
4.1

Explosion protection

The CE and ATEX markings on this unit ensure both a high level of safety and
protection against ignition of the collected combustible dust. However, if an
explosion occurs due to misuse, insufficient maintenance or faulty installation,
this unit is equipped with additional protection methods to avoid dangerous
pressure build-up in the filter.
E-PAK 150 DX/300 DX/500 DX is equipped with either an explosion relief
panel, see Section 4.1.1 Method 1: Explosion relief venting, or an explosion
suppression system, see Section 4.1.2 Method 2: Explosion suppression system.
The suppression system is normally only used if venting is impossible due to
the location of the filter, dangerous material properties or a resulting flame.
4.1.1

Method 1: Explosion relief venting

The harmful effects of an explosion are minimized by venting the pressure
and flame of the explosion through an explosion relief panel. In case of an
26
Risk of explosion.