E-PAK 150 DX/300 DX/500 DX
8
Installation
8.1
Installing E-PAK 150 DX/300 DX/500 DX
WARNING!
The outlet silencer and fan may reach high temperatures during normal
operation.
WARNING!
Always stop the unit before looking into the outlet. The fan rotates at high
speed and debris and particles coming out of the outlet may cause eye injuries.
E-PAK 150 DX/300 DX/500 DX may be placed indoors or outdoors.
Consider the following when installing E-PAK 150 DX/300 DX/500 DX:
•
The foundation is to be level and hard, see Section '7.2.2 Foundation'.
•
Do not install E-PAK 150 DX/300 DX/500 DX close to heat sources or
hot surfaces.
•
Beware of hot air from the outlet.
•
Ensure that handling is convenient.
•
Ensure that emptying collected dust is convenient.
•
Ensure that service and maintenance are convenient.
•
In case of high relative humidity, do not expose
E-PAK 150 DX/300 DX/500 DX to freezing temperatures.
•
Do not place E-PAK 150 DX/300 DX/500 DX in direct sunlight.
NOTE!
suppression systems can be found in the suppression system manual. Work is
only to be carried out by certified personnel.
8.1.1
Indoor installation
Ensure that the room where the unit is to be installed is well ventilated.
NOTE!
installed completely!
In some conditions, the unit may draw air directly into the high-pressure fan.
This may cause a dangerous underpressure in the room if air cannot enter
freely. There are to be two openings for ventilation, at least 250×250 mm
(10"×10") in size. One is to be placed up high and the other one down low.
8.1.2
Outdoor installation
If installed outdoors, also consider the following:
•
Cover the top of the unit to protect it from snow, rain or falling debris.
•
Install a lightning conductor, see Section '8.3 Electrical installation'.
8.2
Connections
Equipment such as cables and hoses is not supplied and is to be obtained
locally.
34
Risk of personal injuries.
Risk of eye injuries.
Detailed information regarding installation of an explosion
Never seal a small room with a E-PAK 150 DX/300 DX/500 DX