RIB DUKE Serie Manual Del Usuario página 20

Operador irreversible para cancelas de batiente
Ocultar thumbs Ver también para DUKE Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G
B
I
NsTALLING THE DUKE 180°
- Make sure that the pivot of foundation box is well greased. lay down the
ball (CVA1479) end insert drive rod CME5230 after fitting release system
(picture 7).
- Fit gate bracket plate CME6987 through its pivot in the drive rod (picture
8).
- Place gate leaf between upper hinge and plate of gate bracket (hinge and
pivot of gate bracket plate should be perfectly aligned).
- Weld carefully bracket plate on the leaf.
- Fit Duke operator inside foundation box (picture 12) by means of enclosed
nuts M12 and washers on column side, while on opposite column side
screw in "prolunghe" CME5228 and relevant washers Drl12X24 (refer
to exploded view at last page). ATTENTION: Duke motor must be always
placed as in picture 12 (motor on right side), no matter right or left side.
- Fit gearing plate by means of relevant nuts and washers M10.
- insert bolt and nut for adjusting (A) (Picture 12).
- insert gear train CME5226 into splined drive shaft, after fitting adjusting
bolt b as in picture 12. ATTENTION: adjusting of opening travel must
be done by adjusting bolt b, but amplitude is regulated by position of
insertion of drive shaft. The wider the opening is needed the closer to stop
1 it must be inserted (for left side fitting), or stop 2 (for right side fitting).
A
DJUsTMENT Of DUKE 110° MECHANICAL sTOPPEr
The DUKE system requires no floor stops or other accessories as the
gate travel limit is determined by means of set screws located internally
of the box.
Access to the screws is gained by lifting the cover.
- To adjust the travel limit for the opening movement of the gate, simply
turn the screw (A) left or right as appropriate, then secure the lock
nut to prevent the screw from slipping out of position subsequently
(Fig. 11).
Same adjusting must be done also on bolt (C) for closing, in order to let the
mechanism block again when unblocked.
IMPOrTANT: Please make sure that the leaves stop
against the mechanical stoppers inside
the operator before they reached the
ground mechanical stopper. In not
adjusted, unblocking will be impossible.
A
DJUsTMENT Of DUKE 180° MECHANICAL sTOPPEr
To adjust the travel limits to the required positions, simply turn the
relative screws A and B left or right as appropriate, then secure
the locks nuts to prevent the screws from slipping out of position
subsequently (Fig. 12).
before this adjustment is made, the angular position of the stop must be
selected according to the maximum opening arc required:
A = CLOsING sTOP
Adjusting must be done in order to let the mechanism block again when
unblocked.
B = OPENING sTOP
ATTENTION: further to adjusting opening bolt, it is necessary to insert drive
shaft approximately towards the stop where adjusting bolt will end (2 for left
side and 1 for right side).
IMPOrTANT: Please make sure that the leaves stop
against the mechanical stoppers inside
the operator before they reached the
ground mechanical stopper. In not
adjusted, unblocking will be impossible.
C
sX
2
B
GATE SHUT
2
B
0
0
DX
A
CCA1360
GATE SHUT
A
1
DX
A
1
11
12
Tabla de contenido
loading

Este manual también es adecuado para:

Duke 110Duke 180Aa10975Aa10985

Tabla de contenido