Logic
Default Definition
Fixed code
OFF
fixed code
Remote control
ON
radio prog
programming
ON
1 motor active
1
ot. on
Gate open light or
OFF
sca-2ch
2nd radio channel
press
Closing limit
OFF
swc
switch pressure
(special dip 1*)
lg1
OFF
Logica 1
(special dip 2*)
LG2
Logica 2
OFF
(special dip 3*)
*=Refer for universal handheld programmer.
12.3) TABLE C: RADIO MENU (RADIO)
Description
Add Start Key
Add start
associates the desired key with the Start command.
Add 2ch Key
add 2ch
associates the desired key with the 2nd radio channel command.
Read
Checks a key of a receiver and, if memorized, returns the position of the remote control in the memory (from 01 to 63) and number of the key
read
(T1-T2-T3 or T4).
Erase List
erase 64
WARNING! Erases all memorized remote controls from the receiver's memory.
Read receiver code
Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time
the W LINK remote control is last pressed.
OFF= W LINK programming disabled.
16 - HYDRA N
INSTALLATION MANUAL
Cross out
setting
Description
used
ON
Receiver is configured for operation in fixed-code mode.
OFF
Receiver is configured for operation in rolling-code mode.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has
already been memorized in standard mode via the radio menu.
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be
ON
memorized.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new
transmitters.
This mode does not require access to the control panel.
Disables wireless memorizing of transmitters.
OFF
Transmitters are memorized only using the relevant Radio menu.
Checks 2nd motor, where applicable (connected to terminals 1 and 2) in parallel with main motor. There
ON
is no need to connect the opening limit switch relating to 2nd motor (PHEBE N SQ terminals 9-10).
See Fig.H Ref.2-3.
Checks 2nd motor (connected to terminals 1 and 2) independently from 1st motor. The opening limit
OFF
switch needs to be connected to 2nd motor (PHEBE N SQ terminals 9-10). See Fig.H Ref.2 or 3.
ON
The output between terminals 11-12 is set as gate open light.
OFF
The output between terminals 11-12 is set as 2nd radio channel
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor
ON
interpreting this as an obstacle.
Thus the door leaf continues its travel for a further 1,5s, after meeting the limit switch. In this way, the
leaves come to rest perfectly against the stop by allowing the limit switch to trip slightly earlier.
Use when there are no mechanical stops.
OFF
Movement is stopped only when the limit switch trips: in this case, the tripping of the closing limit
switch must be adjusted accurately.
The next operation that is commanded will be used as Autoset (for this to happen, the operation
must
ON
start from the closing travel limit). Once this operation is completed,"LG1" logic is automatically
set to OFF.
OFF
Function disabled.
ON
Terminals 6-7 output as flashing light (bulb connected max. 24V 3W).
OFF
Terminals 6-7 output as solenoid lock.