Listas de parámetros
Núme
Descripción del parámetro
ro del
pará
metro
16-10
Potencia [kW]
16-11
Potencia [HP]
16-12
Tensión motor
16-13
Frecuencia
16-14
Intensidad motor
16-15
Frecuencia [%]
16-16
Par [Nm]
5
5
16-17
Velocidad [RPM]
16-18
Térmico motor
16-19
Temperatura del sensor KTY
16-20
Ángulo motor
16-21
Par [%] res. alto
16-22
Par [%]
16-23
Motor Shaft Power [kW]
16-24
Calibrated Stator Resistance
16-25
Par [Nm] alto
16-3* Estado Drive
16-30
Tensión Bus CC
16-31
System Temp.
16-32
Energía freno / s
16-33
Energía freno / 2 min
16-34
Temp. disipador
16-35
Témico inversor
16-36
Int. Nom. Inv.
16-37
Máx. Int. Inv.
16-38
Estado ctrlador SL
16-39
Temp. tarjeta control
16-40
Buffer de registro lleno.
16-41
Línea estado inf. LCP
16-45
Motor Phase U Current
16-46
Motor Phase V Current
16-47
Motor Phase W Current
16-48
Speed Ref. After Ramp [RPM]
16-49
Origen del fallo de intensidad
16-5* Ref. & realim.
16-50
Referencia externa
16-51
Referencia de pulsos
16-52
Realimentación [Unit]
16-53
Referencia Digi pot
16-57
Feedback [RPM]
16-6* Entradas y salidas
16-60
Entrada digital
16-61
Terminal 53 ajuste conex.
16-62
Entrada analógica 53
16-63
Terminal 54 ajuste conex.
16-64
Entrada analógica 54
16-65
Salida analógica 42 [mA]
16-66
Salida digital [bin]
16-67
Entrada de frecuencia #29 [Hz]
16-68
Entrada de frecuencia #33 [Hz]
252
®
VLT
AutomationDrive FC 301/302
Valor predeterminado
0 kW
0 hp
0 V
0 Hz
0 A
0 %
0 Nm
0 RPM
0 %
0 °C
0 N/A
0 %
0 %
0 kW
0.0000 Ohm
0 Nm
0 V
0 °C
0 kW
0 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] No
0 N/A
0 A
0 A
0 A
0 RPM
0 N/A
0 N/A
0 N/A
0 ReferenceFeedbackUnit
0 N/A
0 RPM
0 N/A
[0] Intensidad
0 N/A
[0] Intensidad
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © 08/2016 Reservados todos los derechos.
4-set-up (4
Sólo FC 302
Cambio
ajustes)
durante
funciona-
miento
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
x
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
x
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
x
FALSE
All set-ups
FALSE
Índice de
Tipo
conversió
n
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int16
67
Int32
0
Uint8
100
Int16
0
Uint16
-1
Int16
0
Int16
1
Int32
-4
Uint32
-1
Int32
0
Uint16
100
Int8
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
100
Uint8
-
Uint8
0
VisStr[50]
-2
Int32
-2
Int32
-2
Int32
67
Int32
0
Uint8
-1
Int16
-1
Int16
-3
Int32
-2
Int16
67
Int32
0
Uint16
-
Uint8
-3
Int32
-
Uint8
-3
Int32
-3
Int16
0
Int16
0
Int32
0
Int32
MG33MM05