This is necessary to ensure correct operation and maintain the stove's life duration. When winter ends,
contact your provider (if he did not contact you) and meet to carry out this maintenance; the following shall be done
(the stove must always be disconnected from power):
5.7.
Review of the daily and weekly cleaning outlets.
5.8.
Cleaning of the exhaust circuit of the stove, cleaning outlets and collector. Always with the stove unplugged.
(Very Important).
To Access to the cleaning outlets, you must open the side doors by removing the screws that keep them
closed, two by each door. Once you have access to these outlets, you must clean it properly, using a wire
brush which is provided with the keyboard in a box. The proper functioning of the stove will depend on its
cleaning.
In the Insert models Ecoaire and Eco II (Drawing 23) you must pull from the stove until having access to the
back part and, this way, to the cleaning outlets.
Cleaning outlet.
In the case of the Atenas model, also remove the front grid (fastened with two screws) to gain access to the
front register.
Frontal Cleaning outlet.
Lower front grille.
It is recommendable to calculate the frequency with which you clean the outlet cleaning considering the
hours of operation, thus avoiding ash saturation.
Once you clean the walls of the stove, you must be sure that the cleaning outlet is securely closed, since the
proper operation of the stove depends on this cleaning.
5.9.
Empty the hopper to take remaining pellets out to avoid pellets absorb humidity.
5.10. Cleaning of the pellets drop tube.
Use the brush provided by ECOFOREST to remove the dust until the end of the tube.
MAINTENANCE AT END OF SEASON OR EVERY 500 KG OF FUEL.
37
Drawing 23
Drawing 24