G
B
O
PERATOR INSTALLATION
According to the chosen opening type (inside or outside) and according
to the chosen max. rotation of the leaf, the bracket must be first cut
respecting the mesurment "a" and than welded as in Fig. 2.
The support must be positioned so that the operator is in perfect
horizontal position.
Attention: do not use the hammer to insert the short brass pivot; the
insertion of the pivot into the fork and bracket must be made simply by
hand pressure (Fig. 3).
Attention: do not incline the hydraulic operator further then the allowed
angle from the oscillating fork (1), could cause the braking of it (1)
(Fig. 4).
58 mm
b
(1)
c
a
(1)
3
58 mm
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote controldevice)
automatic
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated),
like code ACG2020.
B: Key selector with manned operation, like code ACG1010.
C: S afety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
D: Photocells, like code ACG8026.
IDRO DUE 27
Total stroke 270 mm - Max. recommended stroke 250 mm - d = 970 mm
a
b
100
115
100
150
105
110
105
145
120
105
2
120
130
125
125
140
95
140
110
145
95
145
105
150
100
155
85
160
90
170
75
180
65
IDRO 39
Total stroke 390 mm - Max. recommended stroke 370 mm - d = 1210 mm
4
a
b
125
125
130
130
140
140
145
145
145
145
58 mm
160
160
175
175
185
185
185
185
195
195
195
195
240
240
240
240
250
250
250
250
260
260
260
260
270
270
280
280
295
295
If the pillar is too large, and it is not possible to adjust the operator
respecting the measure a, you must make a niche in the pillar or you
5
have to move the gate to the edge of the pillar.
20
20
USE OF THE SHUTTER
Skilled persons
Skilled persons
(out of public area*)
(public area)
A
B
C
C
C
C and D
C and D
C and D
Max. Opening
c
Max. Stroke
(max)
Angle
50
110°
50
90°
55
110°
55
90°
70
105°
70
90°
75
90°
90
100°
90
90°
95
100°
95
90°
100
90°
105
95°
110
90°
120
90°
130
90°
Max. Opening
c
Max. Stroke
(max)
Angle
75
125°
80
125°
90
90°
95
120°
95
90°
110
90°
120
90°
130
110°
130
90°
140
110°
140
90°
185
100°
185
90°
195
95°
195
90°
205
95°
205
90°
215
90°
230
90°
245
90°
Measurements in mm
Unrestricted use
C and D
C and D
C and D
Stroke for
90°
250
215
250
246
215
250
249
225
250
250
250
235
250
255
240
250
250
249
240
250
248
247
Stroke for
90°
368
295
372
300
370
372
310
370
370
370
370
330
370
371
355
370
370
355
370
370
360
370
369
365
370
370
370
369