BTL6-A/G301-M_ _ _ _-A1-S115
Micropulse AT Transducer in round profile housing
9
Technical Data
The following are typical values for an BTL6 with nominal stroke length 500 at DC 24 V and room temperature. Fully
operational after power-up, with full accuracy after warm-up. Values are with BTL6-A-3800-2 or BTL6-A-3801-2 at a
constant offset from the transducer:
Resolution
BTL6-A301
< ±1 mV
BTL6-G301
< ±2 mV
Repeat accuracy
< ±2 mV
Temperature coefficient
typical
< 30
Max. sampling rate
1kHz
stroke-dependent
Non-linearity:
NL
< 500 mm < ±200 µm
NL
> 500 mm < ±0.04 % FS
typ.±0.02 % FS
At relatively slow movement of the
magnets, discrepancies of approx.
2 mV may result.
9.1
Dimensions, weights,
ambient conditions
Nominal length < 1500 mm
➥ ➥ ➥ ➥ ➥ Page 4
Dimensions
Weight
approx. 1.0 kg/m
Housing
anodized aluminum
Operating temp.
0 °C to +70 °C
Humidity < 90 %, non-condensing
Protection class pe IEC 60529
IP 67 when closed up
Shock loading
50 g/6 ms
1
per IEC 60068-2-27
Continuous shock
1
per IEC 60068-2-29
Vibration 12 g, 10 to 2000 Hz
per IEC 60068-2-6
1
1
Individual specifications as per Balluff
factory standard
The CE Mark verifies that
our products meet the
requirements of
EC Directive
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet the
EMC requirements of the following
Generic Standards:
EN 61000-6-4 (emission)
EN 61000-6-2 (noise immunity)
12
english
9.2
Supply voltage (external)
Regulated supply
voltage
Ripple
Current draw
Polarity reverse protection 1.5 * U
ppm/K
9.3
Output signal,
potential-free
Output voltage
BTL6-A301
BTL6-G301
Load current
protected
9.4
Overvoltage protection
Dielectric strength 500 V
to housing
50 g/2 ms
Emission tests:
RF Emission
EN 55011
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Fast transients (Burst)
EN 61000-4-4
Surge
EN 61000-4-5
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
DC 18 ... 30 V
< 0.5 V
ss
100 mA typical
B
0...+10 V
-10...+10 V
< 5 mA short circuit
Group 1, Class A+B
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4
UL authorization
File No.
E227256