Starting The Engine; Stopping The Engine - MTD 02M Manual Del Operador

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Check Oil Level
NOTE: Be sure to check the engine on a level surface with the
engine stopped.
1.
Remove the oil filler cap and wipe the dipstick clean. See
Fig. 10-2.
Oil Fill Cap/
Dipstick
Upper
Level
2.
Insert the dipstick into the oil filler neck, but do not screw
it in.
3.
If the level is low, slowly add oil to the upper limit on the
dipstick. See Fig. 10-2 inset.
4.
Tighten dipstick firmly before starting engine.
NOTE: Do not overfill. Overfilling with oil may cause
smoking, hard starting, spark plug fouling, or oil saturation
of air cleaner.
Fuel Recommendations
Use automotive gasoline (unleaded or low leaded to minimize
combustion chamber deposits) with a minimum of 87 octane.
Gasoline with up to 10% ethanol or 15% MTBE (Methyl Tertiary
Butyl Ether) can be used. Never use an oil/gasoline mixture, dirty
gasoline, or gasoline over 30 days old. Avoid getting dirt, dust, or
water in the fuel tank. DO NOT USE E85 GASOLINE.
WARNING:
explosive under certain conditions. Refuel in a well-
ventilated area with the engine stopped. Do not
smoke or allow flames or sparks in the area where
the engine is refueled or where gasoline is stored.
Avoid repeated or prolonged contact with skin or
breathing of vapor.
WARNING:
should be no fuel in the filler neck). After refueling,
make sure the tank cap is closed properly and
securely. Be careful not to spill fuel when refueling.
Spilled fuel or fuel vapor may ignite. If any fuel is
spilled, make sure the area is dry before starting the
engine.
18
s
9 — e
ectiOn
ngine
Figure 10-2
Gasoline is extremely flammable and is
Do not overfill the fuel tank (there
O
peratiOn
Check Fuel Level
1.
Clean around fuel fill before removing cap to fuel.
2.
Fill tank to approximately 1-inch below lowest portion of
neck to allow for fuel expansion. Be careful not to overfill.
NOTE: Before refueling, allow engine to cool 2 minutes.

Starting The Engine

WARNING:
Always keep hands and feet clear of
equipment moving parts. Do not use a pressurized
starting fluid. Vapors are flammable.
1.
Push primer 1-3 times. Wait about two seconds between
each push. See Fig. 5-1. In temperature around 50°F or
below, prime 3-5 times. After the engine is warmed up, one
prime may be needed for all temperatures.
3
Figure 10-3
2.
Standing behind the mower, squeeze the blade control
against upper handle.
3.
Holding these two handles together firmly, grasp recoil
starter handle and pull rope 1-3 times. See Fig. 5-1. Keeping
a firm grip on the starter handle, let the rope rewind each
time slowly. If engine does not start, it may be necessary to
re-prime the engine.

Stopping The Engine

1.
Release the blade control.