SECURITY LOCK-OUT
The programming pads can be "locked out" so operators
cannot change cycles on their own. When lock-out is
used, the operator can use only the factory-set Automatic
cycles and the one Custom cycle allowed per Select pad.
Before using lock-out, create all desired Custom cycles.
To lock-out, hold SIGNAL pad and press MORE in the
idle mode.
To unlock, hold SIGNAL pad and press LESS in the idle
mode.
TEMPERATURE ADJUSTMENT
Selecting a fabric type selects a preset ideal temperature
for that fabric. Lower temperatures may be needed for
small loads or when airflow through the tumbler is less
than ideal due to inadequate make-up air or exhaust
ducting.
Whenever the control is on, but not in NO HEAT, COOL
DOWN or LOAD READY, pressing the TEMP pad
displays the three digits of the set temperature. Use the
MORE or LESS pad to increase or decrease the
temperature.
To select between Fahrenheit and Celsius display, hold in
the TEMP DISPLAY pad while pressing the TEMP pad.
Fabric
Maximum
Preset Temp
Selection
COTTONS
180° F, 82° C
PERM PRESS
160° F, 71° C
MIXED
140° F, 60° C
DELICATES
120° F, 49° C
Table 8
Temperature Setting Ranges
NOTE: Temperature can be set from 80°F (27°C) to
180°F (82°C) in the Special Cycle and Special Time
options only.
To include an adjusted temperature in a Custom cycle,
simply adjust temperature before pressing CUSTOM.
70369801
SHOW MODE
This mode will show all LED's and light up entire display
while deactivating all pads. This mode allows loading
door to be opened and closed. To enter this mode, the
control must first be in the idle mode. Hold the START
pad and press the SAVE CUSTOM pad. To exit Show
Mode, hold the START pad and press the SAVE
CUSTOM pad.
TEMPERATURE SENSOR
To test the temperature sensor, hold COOL DOWN pad
and press the TEMP pad in the idle mode. This will show
the temperature detected by the control.
"SH" displays and signal sounds if the temperature
sensor is shorted or sensor temperature is over 200°F
(93°C). Press the STOP/RESET pad twice within 3
seconds and allow the tumbler to cool, then press an ON/
SELECT pad. If "SH" still displays, call for service.
"OP" displays and signal sounds 3 minutes after the
tumbler is started if the temperature sensor is faulty or if
a temperature below 24°F (-4.4°C) is detected. If dryer
temperature is above 24°F (-4.4°C), call for service.
NOTE: To display the software revision level, hold
the AUTO pad and press the TIME pad while the
control is in idle mode.
Minimum
Temp
160° F, 71° C
140° F, 60° C
120° F, 49° C
100° F, 38° C
59