1.
Install waste port seal carrier by aligning
locating features on waste port seal carrier
to locating features on valve body and
pressing down firmly into position.
4.
Fold down valve hub handle
and install cover assembly.
Operating Instructions
1.
Turn pump off before operating
valve. Depress button on handle to
release latch.
2.
Lubricate inward facing seals of
seal carrier with silicon lubricant
then install seal carriers by firmly
pressing them down into their
respective slots in valve body until
seated.
TIP: Align locating features
between cover assembly
and housing assembly.
2.
While depressing button, rotate
handle until indicator reaches
desired valve position.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3.
Install hub assembly into valve body by
aligning locating features on hub assembly
to locating features on valve body, pressing
down into valve body and ensuring waste
port seal is engaged.
5.
Install lockring, screw
clockwise to tighten.
3.
Release button, allowing
latch to lock handle into
position.