EN
Malfunctions during dispense
Description
Beverage is not exiting dispense tap
Beverage is exiting tap to slowly
Dispensed beverage is warm or not
tasting god
Beverage is dispensed clear but with
too much foam
Foam is exiting from tap with strokes
Foam is not remaining
Beverage is dripping from tap
Bottle of CO2 is emptying too fast
MALFUNCTIONS
Possible reason
1. Barrel is empty
2. Bottle CO2 is empty
3. Valve on CO2 is closed
4. To low pressure in barrel
5. Keg head not connected well on the
barrel
6. Beverage frozen in coil
1. Tap compensator is partly open
2. Keg head is not adjusted properly to
barrel
3. CO2 pressure to low
1. Cooling is not set well
2. To old beverage in barrel
3. Tube and installation set is not
sanitized
1. Glass is too warm
2. Improper dispense technique
3. Too small or to big pressure
1. Keg head not adjusted to barrel
properly
2. No beverage in barrel
1. There are remains of grease or
cleanser
2. Beverage in barrel is too old
1.
1.
Repair description
1. Replace barrel
2. Replace bottle Co2
3. Open the valve
4. Adjust pressure
5. Set keg head properly
6. Call for service
1. Regulator on tap turn opposite
clockwise
2. Adjust keg head
3. Adjust pressure or replace bottle if it
is empty
1. Call for service
2. Replace the barrel
3. Repeat sanitation or call for service
1. Cool down the glass
2. Use proper technique
3. Regulate pressure
1. Adjust keg head
2. Replace the barrel
1. Wash the glass with appropriate
cleanser and rinse in clean water
2. Replace the barrel
1. Call for service
1. Call for service
21